Motor Power Calculation: Torque Determines Whether a Machine Can Move, Power Determines Whether It Can Run Continuously
Release time:
2026-07-09
In motor selection for automation equipment, many engineers start with torque calculation to determine whether the motor can drive the load.
This step is important, but torque alone does not fully determine whether a motor is suitable for an application.
In real projects, it is common to find that a machine can start normally and move the load, but after reaching the target speed, the motor experiences excessive heating, insufficient continuous output, or even overload alarms.
The reason is often not an incorrect torque calculation, but a lack of power verification.
Torque determines whether the motor has enough force to move the load, while power determines whether the motor can continuously deliver the required output at the target speed.
For example, the same 2N·m torque requires completely different power levels at 100rpm and 3000rpm. Therefore, after torque calculation, motor power calculation is also necessary to verify whether the motor can meet the actual operating requirements.

1. Why Torque Alone Is Not Enough for Motor Selection
Motor output can be understood from two aspects.
Torque represents the rotational force generated by the motor and determines whether the motor can drive the load.
Speed represents how fast the motor rotates and determines the movement speed of the equipment.
Power combines both factors and represents how much mechanical energy the motor can deliver within a certain period of time.
A bicycle is a simple example.
When riding uphill, a rider needs to apply greater force to the pedals, but the riding speed is usually lower. When riding at high speed on flat ground, the pedaling force may be lower, but the legs rotate faster and the total energy output increases.
If high speed and climbing ability are required at the same time, the power demand becomes much higher.
The same principle applies to electric motors. A motor with sufficient torque does not necessarily have enough capability for high-speed operation. Only by considering both torque and speed can the actual output capability be evaluated.
2. How to Calculate Motor Power?
The basic mechanical power formula is:
P = T × ω
Where:
- P: Mechanical power (W)
- T: Output torque (N·m)
- ω: Angular velocity (rad/s)
In engineering applications, motor speed is usually expressed in rpm, so the commonly used formula is:
P(kW)=T(N·m)×n(rpm)÷9550
Or:
P(W)=T(N·m)×n(rpm)÷9.55
The two formulas represent the same relationship with different units.
The formula shows that motor power depends on both torque and speed.
Higher torque requires higher power.
Higher speed also requires higher power.
Therefore, when selecting a motor, it is not enough to check only the torque value. The corresponding operating speed must also be considered.
3. Why Does Higher Speed Require More Power at the Same Torque?
Assume a motor continuously outputs 2N·m torque.
At 300rpm:
P = 2 × 300 ÷ 9.55 ≈ 63W
At 3000rpm:
P = 2 × 3000 ÷ 9.55 ≈ 628W
Although the torque remains unchanged, the required power increases by approximately 10 times when the speed increases by 10 times.
This explains why some machines can operate normally at low speed but encounter insufficient output or excessive heating when running faster.
The limitation is not always torque. In many cases, the motor simply cannot provide enough continuous power at the required speed.
4. How to Calculate Power for Linear Motion Systems?
Many automation systems use linear motion mechanisms, such as:
- Ball screw actuators
- Linear modules
- Lifting mechanisms
- Material handling systems
For these applications, the required parameters are usually:
- Thrust force F
- Moving speed v
- Transmission efficiency η
The power calculation formula is:
P = F × v ÷ η
Where:
- F is measured in N
- v is measured in m/s
Example:
Assume:
- Thrust force F = 400N
- Speed v = 500mm/s
- Ball screw efficiency η = 0.9
Convert:
v = 0.5m/s
Then:
P = 400 × 0.5 ÷ 0.9 ≈ 222W
This means the mechanism requires approximately 222W of mechanical output power under this operating condition.
When converting the requirement to the motor shaft, the same result can be obtained.
Ball screw torque:
T = F × p ÷ (2πη)
Ball screw speed:
n = v ÷ p
Then:
P = T × n ÷ 9.55
Whether it is linear motion or rotary motion, the energy relationship is essentially the same:
Linear force × Linear speed = Rotational torque × Motor speed
5. Why Must Transmission Efficiency Be Considered?
In real machines, the energy generated by the motor cannot be transferred to the load with 100% efficiency.
Energy losses occur through:
- Ball screw friction
- Gear reducer efficiency loss
- Belt transmission losses
- Bearing friction
- Guide rail resistance
Therefore, motor power must consider the total transmission efficiency.
The calculation formula is:
P_motor = P_load ÷ η_total
Example:
If the load requires 300W and the total transmission efficiency is 75%:
P_motor = 300 ÷ 0.75 = 400W
The lower the transmission efficiency, the higher the motor output power required.
This is why the same load condition may require different motor sizes when different mechanical transmission structures are used.
6. Motor Power Selection Requires Torque-Speed Curve Analysis
The rated power shown in a motor datasheet is only a reference value.
To determine whether a motor is suitable, engineers should also check the motor torque-speed curve.
Different operating conditions focus on different parameters:
- Low-speed operation: Continuous torque capability
- High-speed operation: Continuous power output
- Acceleration/deceleration: Peak torque and drive capability
- Long-term operation: Temperature rise and thermal capacity
Some motors provide strong torque at low speed but lose output capability at high speed.
Others can deliver high peak performance but cannot operate continuously under heavy load.
Therefore, motor power calculation is not simply about obtaining a watt value. More importantly, it helps determine whether the motor can operate reliably under the actual working conditions.
7. Motor Power Calculation Is Only One Part of Motor Selection
Assume a machine requires:
- Motor output torque: T = 1.5N·m
- Target speed: n = 1500rpm
The mechanical power is:
P = 1.5 × 1500 ÷ 9.55 ≈ 236W
From the power calculation, a 400W servo motor may appear sufficient.
However, before final selection, engineers still need to verify:
- Whether peak torque meets acceleration requirements
- Whether continuous operation causes overheating
- Whether transmission efficiency has been included
- Whether vertical loads require holding torque or brakes
- Whether frequent start-stop cycles exist
Therefore:
Power calculation is an important step in motor selection, but it is not the only factor.
Reliable motor selection requires comprehensive consideration of load, inertia, torque, power, and actual operating conditions.
8. Three Steps for Motor Power Calculation
In practical engineering projects, motor power calculation can be completed through three steps:
Step 1: Determine Load Requirements
Calculate:
- Load force
- Required torque
- Operating speed
- Working cycle
Step 2: Convert Requirements to Motor Shaft Parameters
Based on:
- Gear ratio
- Screw lead
- Transmission efficiency
Calculate:
- Motor output torque
- Motor speed
Step 3: Calculate Power and Verify Motor Performance
Use:
P(kW)=T×n÷9550
Then check:
- Rated power
- Continuous torque
- Peak torque
- Maximum speed
- Temperature rise
Only after these parameters are verified can the motor be confirmed suitable for the application.

9. Five Common Mistakes in Motor Power Calculation
Mistake 1: Looking Only at Power and Ignoring Torque
Motors with the same power rating may provide different torque outputs at different speeds. Low-speed heavy-load applications cannot be selected based only on power.
Mistake 2: Looking Only at Torque and Ignoring Speed
A motor may have enough torque to move the load, but still lack sufficient power for high-speed operation.
Mistake 3: Ignoring Transmission Efficiency
The power required by the load is not equal to the actual motor output power. Mechanical losses must be included.
Mistake 4: Treating Peak Power as Continuous Power
Peak capability only represents short-term output. Continuous operation depends on rated power and thermal capacity.
Mistake 5: Checking Only the Datasheet Value Without the Performance Curve
The suitability of a motor depends on the complete torque-speed curve and allowable operating range, not just one rated parameter.
Summary: The Core Logic of Motor Power Calculation
The principle of motor power calculation is straightforward:
Calculate the required torque and operating speed, then determine the mechanical power requirement.
The three most commonly used formulas are:
- P = T × ω
- P(kW) = T × n ÷ 9550
- P = F × v ÷ η
For linear motion systems, power represents the energy required to move a load with a certain force at a certain speed.
For rotary systems, power represents the output capability determined by torque and speed.
In Yikong Intelligent’s mobile robot drive system projects, including AGV drive wheels, low-voltage servo motors, and integrated drive solutions, engineers evaluate multiple factors such as load characteristics, inertia, torque, power, transmission efficiency, and actual operating conditions rather than selecting motors based on a single parameter.
Through systematic calculation and verification, the reliability, efficiency, and service life of equipment can be significantly improved.
Engineering rule of thumb:
Low speed: focus on torque.
High speed: focus on power.
Continuous operation: focus on heat generation.
Final selection should always be based on the complete working condition and motor performance curve.